Failure of A Quick Link At 50kN During Axial Load Testing

Product Testing

Testing Anchors For Breaking Strain

All our mechanical and glue-in anchors conform to EN 959 and meet acceptance criteria for UIAA 123.

We also test load the products we sell in-house…

Failure During Load Testing of A Titanium Glue-In Anchor At 45kN
Ultimate failure strain of a Titan Climbing ‘Eterna’ Titanium Glue-in anchor at 45kN
Titanium Glue-In Staple / U Bolt Anchored Into Rock
Axial loading of a Titan Climbing U glue-in anchor
Quick Links Failed At 50kN During Axial Load Testing
Failure of the testing links at 50kN
Failure of A Quick Link At 50kN During Axial Load Testing
Failure of the testing link at 50kN
Axial Load Testing Stainless Steel Glue-In Anchor
Axial loading of a Titan Climbing ‘Eterna’ glue-in anchor
Stainless Steel Glue-In Anchor Remains Stable After Successful Axial Load Testing
Anchor remains technically functional and not extracted
Axial Load Testing A Twist Leg Glue-In Anchor
Axial loading of a twist leg 6mm x 80mm stainless steel glue-in anchor